Description
Flexible C-arm positioning with a choice of digital detectors
The OX-C605 is a 5 kW mobile digital C-arm X-ray system that combines continuous, pulsed, and digital spot imaging modes with a rotating X-ray tube and adjustable C-arm geometry. Its mobile platform and free-sliding arm design provide a practical arrangement for positioning the system around the imaging area.
Choose between two detector configurations to match your preferred active area, pixel matrix, pixel pitch, and interface. Both options share the same OX-C605 generator, tube specifications, and positioning ranges.
Choose your detector configuration
- Mercu0909F: 210 × 210 mm active area, 1,024 × 1,024 pixels, 205 μm pixel pitch, 2.5 lp/mm spatial resolution, and 1G Ethernet.
- Mercu1212X: a larger 307.2 × 307.2 mm active area, 2,048 × 2,048 pixels, 150 μm pixel pitch, 3.3 lp/mm spatial resolution, and 10G Ethernet.
Key system features
- Three imaging modes: continuous, pulsed, and digital spot operation, with separate voltage and current specifications for each mode.
- Rotating X-ray tube: 0.3 / 0.6 mm focal spots on the shared 5 kW system.
- Defined rotation ranges: 150° total orbital rotation from −33° to +117°, plus 360° lateral rotation (±180°).
- Positioning adjustments: 200 mm horizontal travel, 400 mm vertical travel, and ±15° wig/wag.
- C-arm geometry: 1,000 mm source-to-image distance, 784 mm free space in the arc, and 640 mm arc depth.
- Foot-switch acquisition: image acquisition can be triggered using a foot switch.
- Removable detector grid: available in both detector configurations.
Compare detector specifications
Compare the detector specifications below. The system specifications that follow apply to both configurations.
| Specification | Mercu0909F | Mercu1212X |
|---|---|---|
| Detector | Mercu0909F | Mercu1212X |
| Spatial resolution | 2.5 lp/mm | 3.3 lp/mm |
| Active matrix | 1,024 × 1,024 pixels | 2,048 × 2,048 pixels |
| Pixel pitch | 205 μm | 150 μm |
| Removable grid | Yes | Yes |
| Active area | 210 × 210 mm | 307.2 × 307.2 mm |
| Interface | 1G Ethernet | 10G Ethernet |
Complete shared system specifications
| System model | OX-C605 |
|---|---|
| System power | 5 kW |
| Power input | 110 V AC / 220 V AC |
| Spot / pulsed tube-voltage range | 40–125 kV |
| Continuous tube-voltage range | 40–110 kV |
| Continuous tube current | 6.3 mA |
| Pulsed tube current | 32 mA |
| Digital spot tube current | 100 mA |
| Exposure-time range | 10–1,600 ms |
| mAs range | 0.2–100 mAs |
| X-ray tube type | Rotating |
| Focal spots | 0.3 / 0.6 mm |
| Source-to-image distance (SID) | 1,000 mm |
| Free space in the arc | 784 mm |
| Arc depth | 640 mm |
| Orbital rotation | 150° total (−33° to +117°) |
| Lateral rotation | 360° (±180°) |
| Wig/wag | ±15° |
| Horizontal travel | 200 mm |
| Vertical travel | 400 mm |
Plan your OX-C605 configuration
Start with the detector active area and pixel specifications, then review the system positioning ranges and power input for your facility. NABI Medical Equipment Trading can prepare a quotation based on your selected detector, required quantity, and delivery location.
Request an OX-C605 quotation
Tell NABI Medical Equipment Trading which detector configuration you prefer, along with your required quantity, facility location, and delivery requirements.






Reviews
There are no reviews yet.